Product Details
Home / Product center / Ring main unit / AVR Series 40.5kV (shielded, non-shielded) solid insulation ring network cabinet / AVR 40.5kV Metal Enclosed Solid Insulated Switchgear SIS RMU Ring Main Unit
Contact Us

loading

Share to:
sharethis sharing button

AVR 40.5kV Metal Enclosed Solid Insulated Switchgear SIS RMU Ring Main Unit

The AVR series intelligent compact solid insulation switch equipment is the company based on the development needs of smart grid, integrates "intelligent, energy saving, environmental protection, freevilled", combined with the actual situation and intelligent power grid construction requirements in combination with my country's distribution network. Secondary integration technology, developing production of independent intellectual property, domestic first intelligent permanent magnet (spring) vacuum switching equipment, integral, control, protection, communication and other functions, high intelligence. This product applies to power systems of 50Hz, 12KV, 24KV, 40.5KV, widely used in industrial and civil cable ring networks and power-on-end projects, and is the preferred equipment to ensure power grid safety, reliable, economical and efficient operation.
Availability:
Quantity:
  • AVR-40.5

  • NCE

  • 8535309000

AVR 40.5kV Metal Enclosed Solid Insulated Switchgear SIS RMU Ring Main Unit


The AVR series Metal Enclosed Solid Insulated Switchgear is the company based on the development needs of smart grid, integrates "intelligent, energy saving, environmental protection, freevilled", combined with the actual situation and intelligent power grid construction requirements in combination with my country's distribution network. Secondary integration technology, developing production of independent intellectual property, domestic first intelligent permanent magnet (spring) vacuum switching equipment, integral, control, protection, communication and other functions, high intelligence. This product applies to power systems of 50Hz, 12KV, 24KV, 40.5KV, widely used in industrial and civil cable ring networks and power-on-end projects, and is the preferred equipment to ensure power grid safety, reliable, economical and efficient operation.


Model Description

Enterprise WeChat screenshot _44B8C5F6-9E4E-41FC-AFBA-BB04002573F3

AVR 柜型

Note: For more configuration, please contact us.


Use environment

Name

unit

Environmental value

Amazing air temperature

Maximum temperature

+50

Minimum temperature

--40

Maximum temperature difference

K

30

altitude

m

≤5000

Solar radiation intensity

W / cm2

0.1

Contamination


Ice thickness

mm

10

humidity

Daily relative humidity average

%

≤100

Monthly relative humidity average

≤95

Tolerate earthquake

degree

≤8

Note: Environmental parameters exceed in the above table, please contact us.


Product features

Protective function

The fault current can be automatically identified, realizing the transient current speed, time-limited current speed, timing overcurrent, directional overflow, overvoltage, undercarrons, and cool load start suppression, cold load start suppression break.

Measurement function

It can measure the three-phase current, three-phase voltage, active power, reactive power, active power, reactive power, peak / valley, power factor and frequency.

control function

The local operation and distant control can be realized, and the fault location of the line can be automatically implemented, fault isolation and quickly restore non-fault line power supply, realize the low frequency automatic load, automatic capacitor automatic and related control functions.

Data recording function

Information such as operation, operation, and failure can be automatically recorded.

Intelligent function

On-line integrated analysis of the grid parameters, online monitoring of the performance parameters of the circuit breaker, online programming, can cooperate with the main station of the distribution network, implement remote control management of switching equipment, realize local, distant or hierarchical control Automation system function.



IsolatedOutline map andshapesize

Picture 2

Switch device interval

Switch Device Dimensions (mm)

Total weight (kg)

W

D

H

Eighth spacer

3000

650

1660

1600

Seven intervals

2625

650

1660

1400

Sixth

2250

650

1660

1200

Five-level

1875

650

1660

1000

Four intervals

1500

650

1660

800

Three-horizontal

1125

650

1660

600

Two intervals

750

650

1660

400


IsolatedOutline map and installation dimensions

Picture 3


Switch device interval

Switch Device Dimensions (mm)

Total weight (kg)

W

D

H

Eighth spacer

3000

905

1660

1760

Seven intervals

2625

905

1660

1540

Sixth

2250

905

1660

1320

Five-level

1875

905

1660

1100

Four intervals

1500

905

1660

880

Three-horizontal

1125

905

1660

660

Two intervals

840

905

1660

440


Picture 4


Switch device interval

Switch Device Dimensions (mm)

Total weight (kg)

W

D

H

Sixth

3000

780

1800

2240

Five-level

2500

780

1800

1860

Four intervals

2000

780

1800

1480

Three-horizontal

1500

780

1800

1100

Two intervals

1000

780

1800

740



Outline map andshapesize

Picture 5

Switch device interval

Switch Device Dimensions (mm)

Total weight (kg)

W

D

H

Five-level

3500

1130

2200

3750

Four intervals

2800

1130

2200

3000

Three-horizontal

2100

1130

2200

2250

Two intervals

1400

1130

2200

1500





Rated voltage

KV

12

24

40.5

Rated current

A

630/1250

630/1250

1600

Rated frequency

Hz

50

Rated short (1min) power frequency tolerance voltage (on ground / broken)

KV

42/48

65/79

95

Rated lightning impact tolerance voltage (on ground / broken)

KV

75/85

125/145

185

Rated short circuit opening current

ka

20/25

25

25

Rated short-circuitry current (peak)

ka

50/63

63

63

Rated short-term resistance (4S)

ka

20/25

63

63

Rated peak tolerance

ka

50/63

63

63

Rated short-circuit current break

30

Operating agency


Permanent magnet / spring

Vacuum circuit breaker mechanical life

1000 (30000 permanent magnet)

Life of isolation / ground switch

3000

Enclosure rating


IP4X

Circuit breaker rated operation order


O-0.3S-CO-180S-CO

Note: Technical parameters exceed the scope of the previous table, please contact us



The main switch and the ground switch have mechanical interlocking functions.

The switch is operated by a dedicated operating handle, and the operation speed and strength of the contact are determined by the operating mechanism spring, and the change is changed due to the different operators. When the switch is hierarchically, the speed of the contact is rely on the speed and the arc gate to extinguish the arc, and the arc current is cut immediately.

The switch operation holes can be locked with a bright lock to prevent errors.

The switch main mechanism and grounding mechanism use spring storage operators, structural stability, less components, low failure rate, and significantly improved product reliability, and the mechanical life is as high as 10,000.

The key components use non-ferrous metal materials such as aluminum alloys. Other components use high-density carbon steel, treated by 8 steps, and finally baking highly attached outdoor military powder, ensuring institutional performance.

The mechanism interlock is directly fixed to the main body of the main mechanism and the ground mechanism, ensuring that the interlock indication is consistent with the actual position of the switch and prevents errors.

Electric operating mechanism: When a set of electric motors and attachments are installed on the basis of the original manual operating mechanism, it can be extended as an electric operating mechanism.

The switch adopts foreign technology. The key components use imported products, and the modular contacts are highly conductive and high-conducting tabs, the auxiliary silver process, so that their comprehensive conductive capacity is significantly improved, and the temperature rise is clearly smaller than the similar imported products.

Move, the static contacts are valid for 105mm, leading to the domestic leading, maximizing the insulation performance of the product under the zero table.

The FTU can be installed to realize the transient current speed, time-limited current speed, timing overcurrent, etc., and can remotely control the ring switch device.

Note: For additional functional requirements, please contact our company.

Previous: 
Next: 

join us

Quick Links

News center
 Business Contact: +86 18151061969
Recruitment hotline: 0514-87849128
Purchasing consultation: 0514-87849108
 
 

Copyright © ️ 2021 New Concept Electric Inc. Technical Support:Focus leader Su ICP 20001825 -1